These are generated by the device itself based on its built-in hardware or firmware logic, such as speeding or blind spot detection. A device will report these alerts regardless of the platform it is connected to.

Platform-calculated alerts are generated by the platform based on secondary calculations of data reported by the device. The calculation rules and alert types may differ between platforms.

Administrators can configure these alerts in the Customer Management System (CMS) according to business needs. They are sent immediately when trigger conditions are met.

Users can configure complex rules in the Customer Management System (CMS) based on devices, alerts, and geofences. When a rule is triggered, the system sends an alert notification.


  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Platform Calculated
  • Trigger Rule: The device speed remains below 5km/h for 3 consecutive minutes with the ACC in the ON state.
  • End Rule: The ACC changes to OFF or the speed exceeds 5km/h.
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Platform Calculated
  • Trigger Rule: The device’s location information leaves the customer-created geofence.
  • Source: Platform Calculated
  • Trigger Rule: The device’s location information enters the customer-created geofence.
  • Source: Platform Calculated
  • Source: Platform Calculated
  • Trigger Rule: The device’s ACC status changes to on.
  • Source: Platform Calculated
  • Trigger Rule: The device’s ACC status changes to off.
  • Source: Platform Calculated
  • Trigger Rule: The device’s I/O status changes to connected.
  • Source: Platform Calculated
  • Trigger Rule: The device’s I/O status changes to disconnected.
  • Source: Platform Calculated
  • Trigger Rule: The current number of passengers in the vehicle exceeds the set maximum passenger capacity.
  • End Rule: The number of passengers is less than or equal to the maximum capacity, or the passenger overload end time is exceeded.
  • Source: Platform Calculated
  • Trigger Rule: An ACC ON event is reported by the device, but the current time is outside of any preset work schedule.
  • End Rule: The time reported by the device is within the work schedule, or an ACC OFF is reported outside of the schedule.
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Trigger Rule: An alarm is generated when the alcohol concentration value (BAC) detected by the device is greater than or equal to the preset threshold.
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Device
  • Source: Track series device
  • Trigger Rule: The device begins to upload real-time coordinate points that are not located.
  • Source: Track series device
  • Trigger Rule: The device transitions from uploading non-located coordinate points to uploading located coordinate points.
  • Source: Platform Calculated
  • Trigger Rule: The device begins to upload real-time coordinate points that are not located.
  • End Rule: The device begins to upload real-time coordinate points that are located.
  • Source: Device
  • Source: Device
  • Source: Device